4.3 LOGs
For the current LOG records see the sectionGateway / Gateway control – LOG file
or use the AT&L AT command for Telnet sessions. The following list of LOG statuses is
universal and some LOGs may not be included in :2N VoiceBlue Next
®
Type Text Description
POWER
[Power on] System switched on
[Power off] System switched off
[Warm boot] Restart of system, unknown cause
[Watchdog] Restart of system by watchdog
[BKPT code] CPU error: break code detected
[Stack error] CPU error: stock integrity failure
[Divided by
zero]
CPU error: dividing by zero
[RETI code] CPU error: illegal using of instruction reti
[NMI intr] CPU error: wrong interrupt
[VOID intr] CPU error: wrong interrupt
[Upgrade reset] Start of upgrade firmware procedure
[Software
reset]
Reset by AT commands (at&fres…)
INIT
Eeprom Initialisation of eeprom (configuration)
Flash Initialisation of flash memory (firmware)
HW–ERR
(##…address of chip, RD…read value/WR…expected
value)
Codec
##,RD/WR
Error in initialisation of codec on GSM,AUX board
COM2
#####,RD/WR
Error in initialisation of COM2 on AUX board
Duart
#####,RD/WR
Error in initialisation of serial controller on GSM board
Hscx
#####,RD/WR
Error in initialisation of HDLC controller on AUX board
Pri
#####,RD/WR
Error in initialisation of PRI controller
SYSERR
User stack
error!
SW error: stock integrity failure
BRDIN #08 TYP STS Board inserted (number of gsm board, type, status)
BRDOUT #08 TYP STS Board disconnected
BRDRES #08 TYP STS Reset the board by AT command