2n Omega series - Configuration Tool manual v1.10 Manuel d'utilisateur Page 80

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 114
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 79
80
2.8. Switches
Set the binary switch actions in this MENU section. You can create a table of
actions for each binary switch and specify for each switch which actions should be
executed upon its status change. You can set general switch actions for the whole
PBX or a group (1, 2) too.
2.8.1. Switch Settings
The table above shows all the switches installed in the PBX.
Type define the switch as a Binary input, or Relay contact.
State select OFF/ON for the Relay mode. The required Relay change will
occur when the configuration is stored in the PBX. With Binary, this field is
non-editable.
Group select whether or not the Binary input actions should affect a
selected group (DAY/NIGHT switching option). If no group is selected, the
subsequent actions are governed by the ON/OFF states independently on
the DAY/NIGHT mode.
ON-state the assigned action table is executed if the binary input transits
from the so-called logical 1, or the contact ON-state (e.g. motion sensor at
rest), into the so-called logical 0, or the contact OFF-state (e.g. motion
sensor activation).
OFF-state the assigned action table is executed if the binary input
changes from the so-called logical 0, or the contact OFF-state (e.g. motion
sensor active) into the so-called logical 1, or the contact ON-state (e.g.
motion sensor idle).
Day/Night applies to selected groups 1 or 2.
To assign a table, select one of the created ones, or create a new one. Use the
New command to open the action table defining dialogue.